Chapter 2 TL1 Reference
Set Communication Parameters
140 SSU-2000 Technical Reference 12713020-003-2 Revision F.01 – January 2007
Set Communication Parameters
This command allows you to set the parameters for the serial communications
ports. Use this command to choose between the ICS and TL1 command mode.
Syntax
SET-PRMTR-COMM:[tid]:[aid]:ctag::[baud],[echo],[eol], [mode],[tout];
Empty fields leave parameters unchanged.
Related Commands
Retrieve Communication Parameters, on page 48
Parameter Format Description
aid ALL, COML,
COMA, COMB,
TELNET, or
TL1
Sets the parameters for the specified communications
port.
baud 19200|9600
|4800|2400
|1200
Sets the communications baud rate for the specified port.
echo ON | OFF Sets the unit to use full (On) or half duplex (Off).
eol CR | LF |
CRLF
Sets the end-of-line character(s) sent by the unit .
mode ASCII |
TL1
Sets the mode of communication.
tout 5 – 43200
| NEVER
Sets
the inactivity timeout period in seconds.

Table of Contents

Other manuals for Symmetricom SSU-2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom SSU-2000 and is the answer not in the manual?

Symmetricom SSU-2000 Specifications

General IconGeneral
BrandSymmetricom
ModelSSU-2000
CategoryPower Supply
LanguageEnglish

Related product manuals