Chapter 2 TL1 Reference
Set Operating Mode
164 SSU-2000 Technical Reference 12713020-003-2 Revision F.01 – January 2007
Set Operating Mode
This command sets the Operating Mode for the system.
Syntax
SET-PRMTR-OPERMODE:[tid]::ctag::mode;
where:
NORMAL = SSU is in normal master mode. In this mode, the unit selects an input
reference from any available input sources.
SUBTENDING = SSU is in ANSI subtending mode. In this mode, the unit
chooses an available Composite Clock Input as an input reference. All other
inputs shall not be selected as input reference.
JAPANESE = SSU is in Japanese subtending mode. In this mode, the unit
chooses an available Japanese Composite Clock Input as an input reference. All
other inputs shall not be selected as input reference.
Related Commands
Retrieve Operating Mode, on page 97
Parameter Format Description
mode normal |
subtending
Japanese
Sets the operating mode.