Chapter 2 TL1 Reference
Set JCC Output Parameters
156 SSU-2000 Technical Reference 12713020-003-2 Revision F.01 – January 2007
Set JCC Output Parameters
This command sets the parameters for the specified Japan Composite Clock Output
module or port.
Syntax
SET-PRMTR-OUTJCC:[tid]:[aid]:ctag::[pstate],[bypass],[400hz],[pcomp];
Empty fields leave parameters unchanged.
Related Commands
Retrieve JCC Output Parameters, on page 82
Parameter Format Description
aid SxAy[-z] Sets the parameters for the specfied JCC Output module
[or port].
pstate ON | OFF Enables or disables the specified module [or port].
bypass ON | OFF Allows operation when Clock C is the active clock.
400hz ON | OFF Enables or disables the 400 Hz BPV removal.
pcomp 0 - 7 Sets the phase compensation delay, where 7 = No
compensation and 0 = 2200 ft; the resolution of pcomp
values is 275 ft.