Chapter 2 TL1 Reference
Retrieve Input Status
74 SSU-2000 Technical Reference 12713020-003-2 Revision F.01 – January 2007
Retrieve Input Status
This command returns the condition (current operating mode and readings) of the
input ports.
Syntax
RTRV-STATUS-INPUT:[tid]:[aid]:ctag;
Response Format
One line is returned for each port designated by the aid.
^^^"aid:mstat,pstate,(pha),(phb),pql" <cr lf>
where:
aid = module or port access identifier
mstat = module status {OK | DIS | FLT}
pstate = the port state {OK | DIS | FLT}
pha and phb = current 1-second phase values in nanoseconds, or NA if not
available
pql = current pql level (read or provisioned) being reported by the port, if
available. If pql = 0 , then the pql is not applicable for that port.
Example
SSU_2000 06-03-08 20:28:19
M 100 COMPLD
"S1A03-01:OK,OK,(-29),(-8),2"
"S1A04-01:OK,OK,(-20),(-72),4"
"S1A05-01:OK,DIS,NA,NA,4"
;
Parameter Value Description
[aid] ALL Retrieves the parameters from all Input modules in the
shelf.
S1Ay[-z] Retrieves parameters from the specified Input module [or
port].

Table of Contents

Other manuals for Symmetricom SSU-2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom SSU-2000 and is the answer not in the manual?

Symmetricom SSU-2000 Specifications

General IconGeneral
BrandSymmetricom
ModelSSU-2000
CategoryPower Supply
LanguageEnglish

Related product manuals