12713020-003-2 Revision F.01 – January 2007 SSU-2000 Technical Reference 169
Chapter 2 TL1 Reference
Set Phase Build-Out Parameter
Set Phase Build-Out Parameter
This command determines whether an event is displayed and/or stored when a
Phase Build-Out occurs on DS1, E1, and Japan Sine Input modules.
Syntax
SET-PRMTR-PBO:[tid]::ctag::mode;
Related Command
Retrieve Phase Build-Out Parameters, on page 102
Parameter Format Description
mode DIS | EVT
REP | NONE
DIS – Disables the function
EVT – enables the PBO function. The PBO event is
displayed and stored in the COMM module event
buffer.
REP – enables the PBO function. The PBO event is
displayed, but the event is not stored in the COMM
module event buffer.
NONE – enables the PBO function. The PBO event is
neither displayed nor stored in the COMM module
event buffer.