12713020-003-2 Revision F.01 – January 2007 SSU-2000 Technical Reference 315
Chapter 6 Alarms and Events
Japan Sine Input Module Alarms and Events
201 Priority, 5, COML A user has changed input priority level.
203 Prov PQL, 5, COML A user has changed input provisioned PQL.
204 MTIE Err Limit, T100, L1, 550,
COML
A user has changed input MTIE limits (L1 | L2).
206 CSFlt, Off, COML A user has changed input Cesium Fault control.
209 Freq Err Limit, Clk-A, 100, COML The frequency error limit settings have been changed.
210
Freq Clr Limit, Clk-A, 800, COML
The frequency clear limit settings have been changed.
211 MTIE Clr Limit, T100, L1, 500,
COML
The MTIE error limit settings have been changed.
212 MTIE Limit, DS1, COML, Setting The MTIE clear limit settings have been changed.
213 PBO, Report, COML Phase Build-out system response has been changed to the
indicated setting.
214 Freq Tau, Clk-A, 400, COML The frequency TAU limits have been set.
224 IoName, Set A user has set the IO Name.
251
Err Delay, (0), 10 sec, COML
An alarm delay time change.
252 Alm Level, (2), Maj, COML An alarm level change.
253 Elevate Time 86400 sec, COML An alarm elevation time change.
254 Setup, Save, COML User defaults have been set and saved.
Table 6-17. Japan Sine Input Module Alarm Defaults
ID Description Alarm Level
000 LOS Major
005 MTIE/L1 Minor
006 MTIE/L2 Major
007 CS Fault Minor
009 Ref Qualifier Minor
010 Clock PLL Major
011 Input PLL Major
012 Phase Hdw Major
013 FREQ Minor
014 Hdw Config Major
Table 6-16. Japan Sine Input Module Alarm and Event Messages (Continued)
Alarm/
Event/
Trap ID
Typical Alarm/Event/Trap
Response
Description/
Corrective Action