Chapter 3 ICS Command Reference
SNMP
246 SSU-2000 Technical Reference 12713020-003-2 Revision F.01 – January 2007
V2USER SNMPv2 User Table
INIT Clears the whole SNMP user table and only leaves the
built-in users in the systems. This option clears the table.
ADD Adds the SNMP user “read community” to the system. If the
user exists in the system this option exits with an error.
After the read community string is entered, this command
prompts for a write community. Write Community entries
are echoed as ‘*’. Valid write community characters are all
upper alphanumerical characters. After the write
community string is entered, this command prompts for the
user level.
MODIFY Modifies the write community and/or the access level for
the given user. If the user id is not in the system, this
command exits with an error. Once the user is entered, this
option performs identically to the ‘ADD’ option.
DELETE Deletes the user from system. If the user id is not in the
system, this command exits with an error.
V2MANAGER SNMPv2 Manager Table
INIT Initializes the SNMP Manager Table to all null IP addresses.
ADD Adds an SNMP Manager IP address into the SNMPv2
Manager Table.
DELETE Deletes an SNMP Manager IP address from the SNMPv2
Manager Table.
V3USER SNMPv3 User Table.
INIT Clears the whole SNMPv3 user table and leaves only the
built-in users in the systems.
ADD Adds the SNMP user “read community” to the system. If the
user exists in the system this option exits with an error.
Then this command shall prompt you to enter
authentication algorithm (HMAC-MD5 or HMAC-SHA).
After the authentication algorithm is chosen, this command
prompts for authentication key and privacy key. The
Authentication and Privacy entries are echoed as ‘*’. Valid
authentication and privacy characters are all upper-case
alphanumerical characters.
Note: Except for the first built-in entry, Read community: ‘public’ and
Write community: ‘private’, all user-added community strings are in
upper case. You can have up to five SNMPv2 user entries, including
the built-in user.

Table of Contents

Other manuals for Symmetricom SSU-2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom SSU-2000 and is the answer not in the manual?

Symmetricom SSU-2000 Specifications

General IconGeneral
BrandSymmetricom
ModelSSU-2000
CategoryPower Supply
LanguageEnglish

Related product manuals