12713020-003-2 Revision F.01 – January 2007 SSU-2000 Technical Reference 29
Chapter 2 TL1 Reference
TL1 Command and Response Conventions
"response message" is the response message. The response message line for
complied messages always begins with 3 spaces (^^^) followed by the response
message enclosed in quotation marks, and terminated by <cr lf>. Multiple lines of
response messages are allowed. Each command response is terminated by a
semicolon following the last <cr lf>.
DENY Output Response Message Conventions – The DENY response contains
a four-character error code (ercd) that describes the reason for the denied
response. For example, the error code ICNV indicates Input Command Not Valid.
The error codes are listed in Table 2-1.
The SSU-2000 sends the DENY response when:
the cmd is not valid
the aid is not valid
the ctag is not valid, indicated by a response containing the ctag set to a single
zero character (0)
the unit is unable to comply with the request for the reason indicated by the ercd
The format for a denied (DENY) output response message is:
<cr lf lf>
^^^sid^date^time <cr lf>
M^^ctag^DENY <cr lf>
^^^ercd <cr lf>
where:
sid (Source Identifier) is the returned ID, and is the same as the tid in the input
command message
date is the current year, month, and day in the SSU-2000 in the format:
YY-MM-DD.
time is the current hours, minutes, and seconds timestamp information in the
SSU-2000 in the 24-hour format: HH:MM:SS
ctag (Correlation Tag) field is a six-digit alpha-numeric message identifier code
that is received with the command and returned in the response, for correlation of
message and response within the operating system
DENY is the deny message
ercd (Error Code) is a four-character error code that explains the reason for the
deny, and is one of the following defined codes (other error codes may be
defined and used, if required).

Table of Contents

Other manuals for Symmetricom SSU-2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom SSU-2000 and is the answer not in the manual?

Symmetricom SSU-2000 Specifications

General IconGeneral
BrandSymmetricom
ModelSSU-2000
CategoryPower Supply
LanguageEnglish

Related product manuals