12713020-003-2 Revision F.01 – January 2007 SSU-2000 Technical Reference 299
Chapter 6 Alarms and Events
Communication Module Alarms and Events
151 UTC Time, Valid Time of startup; NTP is enabled but GPS time not being used.
152 TODSYNC, Timeout Time of day (TOD) was requested by the Comms module, no
response from the GPS module.
153 Upload Image, Start System firmware upgrade status.
154 Upgrade, 1A02 Module’s firmware upgrade has started.
155 Upgrade ACK, 1A02 Module’s firmware upgrade was completed.
156 Upgrade NAK, 1A02 Module’s firmware upgrade was not completed.
157 Config, 1A06, Not Support Call Symmetricom Global Services. Return to factory.
158 NTP Mode, GPS The SSU is configured with NTP running in an NTP Client,
Broadcast, or Broadcast Client server mode; Local is displayed
when NTP server is initialized. If GPS is not installed or setup, or
NTP has not been configured NTP remains in Local mode and uses
Comms module time.
159 Reset, Clk-B, COML A user has reset the specified clock.
160 Clk-C Source, 1A04-01 Bypass clock source has changed.
161 Sync Clk-C, Start Status of Sync acquire operation.
192
InitUserTable, JAY, COML
Administrator initialized user database.
193
Add User, DONNA, COML
Administrator added a user to user database
194 Mod User, CALEB, COML User/Administrator modified user database
195 Del User, TEST1, COML Administrator deleted user from user database
196 Pql Table, DS1, pql(5)=ST2,
COML
PQL database has been modified
197 Pql Factory Dflt, COML PQL database has been set to factory defaults
198 Unit Name, , COML The SSU name has been changed
199 NTP Peer Add, 192.5.41.40,
CLIENT, COML
An NTP client was added at the IP address shown
200 NTP Peer Del, 192.5.41.40,
COML
An NTP client was deleted at the IP address shown
201 NTP Brd Timer, 64 seconds,
COML
The NTP broadcast server timer has been set to the interval shown
202 SNMPv2 User, ADD, id=1,
COML
An SNMP user has been added to the user table in the position
shown.
203 SNMP Agent, V2, COML The SNMP mode has been enabled.
Table 6-6. Basic +SNMPv2 and Basic +NTP + SNMPv2 Communications Module Alarm and Event Messages
(Continued)
Alarm/
Event/
Trap ID
Typical Alarm/Event/Trap
Response
Description/
Corrective Action

Table of Contents

Other manuals for Symmetricom SSU-2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom SSU-2000 and is the answer not in the manual?

Symmetricom SSU-2000 Specifications

General IconGeneral
BrandSymmetricom
ModelSSU-2000
CategoryPower Supply
LanguageEnglish

Related product manuals