Service Parts Disassembly
Phaser 3610, WorkCentre 3615 Service Manual4-70
7. Remove the ROS Assembly. (Figure 4)
a. 4 screws (silver, flanged, tapping, 10mm),
b. Disconnect P/J502.
c. Lift to remove the ROS Assembly.
Figure 4
Replacement
1. Make sure the MCU PWB Housing is seated correctly on the pins so it can be rotated back into the
proper position.
2. Replace in reverse order.
s3610-038
P/J502
Front