R5905948 /12 Event Master Devices 179
The Link cards allow for linking multiple Event Master units. Depending on the linking configuration, linked
units share inputs, and they expand the number of layers and outputs. For example, beginning with code
release 6.0, eight (8) E2 units can be linked as a system.
Just as in section Configuration Menu > Network resource area, page 111, the unit that is supposed to be
added is available in the network resource tab. Any second unit can be added, it only needs to have a
separate Unit ID. Change the Unit ID of each system to be different. The default Unit ID is 0 on all E2 chassis
models, 1 on all S3 chassis models, and 2 on the EX chassis. On one of the E2s change the Unit ID to 1 from
the front panel, or by temporarily adding them as separate systems.
A second E2 or S3 4K unit adds fully double capacity from one unit. There are very few limitations to the
capacity and operation is all in all the same as it is for one unit.
After linking chassis, a few menus provide the option of changing between which unit controls you
are viewing.
From the Menu bar at the top of all pages, you can select which processors details you are viewing,
by selecting that processor from the pull down menu.
There is no relationship between Unit ID and Master or Slave selection. Either unit can be Master or
Slave in a linked configuration. The only real significancebut totally transparent to usersis the
Event Master Toolset communicates only with the Master unit. The Master unit establishes its own
connection and handles all communications with the Slave unit(s).
Certain configuration setups are not allowed. These include spanning input or output configurations
between an E2 and an S34K. If your setup requires this kind of configuration, then you must link
together two E2 units or two S34K units.
How to Link Two E2 Units
Each E2 comes equipped with two Link cards, always located in slots 1 and 2. Link cards are identified by a
yellow stripe at the top. Make sure to use the locking mechanism and then push each cable until it locks in
place.
Connect the Link cables provided with each E2 between the Link connectors as follows:
VP ID 0, Link Card slot 1, Link 1 >> VP ID 1, Link Card slot 1, Link 2 [1]
VP ID 0, Link Card slot 1, Link 2 >> VP ID 1, Link Card slot 1, Link 1 [2]
VP ID 0, Link Card slot 2, Link 1 >> VP ID 1, Link Card slot 2, Link 2 [3]
VP ID 0, Link Card slot 2, Link 2 >> VP ID 1, Link Card slot 2, Link 1 [4]
See Image 6-45 for an example of the cabling between two E2 units.
Image 6-45: Cabling between two E2 units
EM GUI orientation

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Barco Event Master E2 Series and is the answer not in the manual?

Barco Event Master E2 Series Specifications

General IconGeneral
BrandBarco
ModelEvent Master E2 Series
CategoryDJ Equipment
LanguageEnglish

Related product manuals