The Network List
148 Manpack Transceiver 2110 series Reference Manual
You may need to adjust the nominal preamble from the default value if:
• the transceivers are not scanning identically
• the transceivers are scanning multiple networks
• more than 10 channels are included in the network being scanned
• there is low channel availability due to a poor signal-to-noise ratio, interference, or
high traffic (that is, frequent pausing)
• there are transceivers in the network that are also scanning for voice
If a transceiver you want to call scans multiple networks, the preamble can be increased
to the time it takes that transceiver to scan all of its channels. The nominal preamble
must be set according to the transceiver in the communication network with the slowest
scan cycle.
For Codan Selcall or Open Selcall networks with more than 10 channels in the network,
the nominal preamble for each channel may be set to 0.3 s.
For ALE/CALM networks using Codan HF transceivers that are scanning identically, the
nominal preamble for each channel may be reduced to 0.15 s.
NOTE
The default nominal preamble for each channel in an ALE/CALM
network (see Table 25 on page 147) complies with MIL-STD-188-141B
ALE, and represents two ALE words (0.784 s).

Table of Contents

Other manuals for Codan 2110 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Codan 2110 series and is the answer not in the manual?

Codan 2110 series Specifications

General IconGeneral
BrandCodan
Model2110 series
CategoryTransceiver
LanguageEnglish

Related product manuals