Manpack Transceiver 2110 series Reference Manual 367
24 System messages
This section lists the system messages that may be displayed on the front panel of the
transceiver, and a description of each message. For extended transceiver systems, refer to
the troubleshooting information provided with the system.
Table 53: System messages
Message Description
*** NSP *** NSP is being used to upload or download information to the
transceiver. Wait until NSP has finished. You may need to switch the
transceiver off then on again.
Admin password
incorrect
You have entered an incorrect admin password. Enter the correct
password.
Administrator
logged out
You have logged out of admin level and have returned to user level.
Antenna
untuned
The antenna is no longer tuned. Tune the antenna.
BIT failed:
<name of test and/or reason for
failure>
The built-in test failed. Switch the transceiver off then on again.
Repeat the test.
Call aborted You have aborted the current call by pressing PTT while the call was
being made.
Call already
in progress
A call is currently in progress. End or abort the call before you start
another.
Call
completed
The call in which you were transferring data has been completed.
Call finished
No GPS unit connected
You have sent a Get Position call to a remote transceiver that does not
have a GPS unit connected.
Call error:
bad message
You have pressed so that you can send a message within a
Selective call however, the call system will not accept the message
that you have entered. Check the characters and length of the
message, as only A to Z, 0 to 9, and some punctuation characters are
allowed.
Call error:
call system not configured
The option for the call system with which you have attempted to
make a call has not been installed in the transceiver. Select a network
with a different call system or, if you know the option code for the
call system, install it using the Option code setting under the Devices
entry in the Control List (see page 253, Installing an option in the
transceiver).
Call error:
check cables then restart
tcvr
An error has occurred in a device. Switch off the transceiver, check
that the cables are connected correctly, then switch on the transceiver.
If the problem persists, contact your Codan representative.

Table of Contents

Other manuals for Codan 2110 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Codan 2110 series and is the answer not in the manual?

Codan 2110 series Specifications

General IconGeneral
BrandCodan
Model2110 series
CategoryTransceiver
LanguageEnglish

Related product manuals