Using the 9350 Automatic Tuning Whip Antenna with a 2110 Manpack Transceiver
Manpack Transceiver 2110 series Reference Manual 63
Testing the installation
Following correct installation, the station should be tested for correct operation prior to
use in the HF network.
Testing involves:
measuring the SWR
carrying out station-to-station on-air testing
Standing wave ratio
The 2110 series Manpack Transceiver measures the forward and reflected powers
between a transceiver and its antenna load, and represents these in a ratio called the
SWR. To ensure correct installation, the power and SWR assessment should be
performed with the transceiver working in its normal antenna system. Press TUNE to see
the SWR, then press PTT to manually tune the antenna.
If the impedance of the antenna is equal to 50 , no power is reflected. This is the ideal
situation, which gives an SWR reading of 1:1. An SWR equal to or lower than 2:1 is
acceptable. If the SWR is greater than 2:1, the ALC circuitry in the transceiver reduces
the output power. With some combinations of frequencies and antenna design, it may not
be possible to achieve the desired figure on all channels.
Using SWR to test the installation
To test the installation:
1 Select the highest operating frequency of the transceiver.
1 Connect the SWR meter to the coaxial line at the base of the antenna.
1 Tune the antenna.
If the antenna installation parameters are within the satisfactory operating range,
tuning will be successful and the SWR reading will be less than 2:1.
1 Select the lowest operating frequency of the transceiver, then repeat the test.
1 If a particular channel frequency does not tune, check the conductivity of the
grounding system.
WARNING
Before using the antenna system see the safety information provided on
page 491, Radiation safety.
CAUTION The SWR should never rise above 2.5:1.

Table of Contents

Other manuals for Codan 2110 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Codan 2110 series and is the answer not in the manual?

Codan 2110 series Specifications

General IconGeneral
BrandCodan
Model2110 series
CategoryTransceiver
LanguageEnglish

Related product manuals