EasyManuals Logo

Codan 2110 series User Manual

Codan 2110 series
521 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #99 background imageLoading...
Page #99 background image
Operating the transceiver
Manpack Transceiver 2110 series Reference Manual 83
Muting the transceiver
When the transceiver is set to a channel or is scanning channels, and mute is switched
off, you hear noise on each channel. If you do not want to listen to this noise, you can
silence the transceiver by switching mute on.
Mute automatically comes on when the transceiver starts scanning. You must set the
Mute Scan entry in the Control List to:
• Selcall if you want the mute to open when a call addressed to your station is
detected, or voice is detected on a channel in a voice network
• Voice if you want the mute to open when a voice signal is detected (you can alter
the call detect time across Codan Selcall networks)
• Scan for Voice if you want the mute to open when a voice signal is detected on
any network (the transceiver scans at a uniform rate across all networks)
If the scan is paused due to voice being detected, the length of time that the transceiver
holds the pause is set in the Cfg Scan Voice Max Hold and Cfg Scan Voice Extend
entries in the Control List. Scanning only resumes automatically if the transceiver is set
to start scanning after a timeout period (see page 250, Auto Resume entries).
Switching mute on or off
To switch mute on or off:
1 Press MUTE.
A message is displayed briefly to inform you that mute has been switched on or off.
The V or S on the channel screen is highlighted when mute is on.
Setting the mute type
To select the mute type:
1 Press V/S to toggle the mute type between Selcall mute (S) and Voice mute (V).
NOTE
In the following discussion, you must log in as administrator to see the
entries in the Control List (see page 128, Logging in to admin level from
user level).
NOTE
For help with changing these entries in the Control List see page 228,
Entries in the Control List and page 112, Changing a setting in the
Control List.
NOTE
If you have the AES-256 digital voice encryptor fitted, an additional
mute type of Digital Voice Only mute (D) is available. For more
information see page 296, Using digital mute.

Table of Contents

Other manuals for Codan 2110 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Codan 2110 series and is the answer not in the manual?

Codan 2110 series Specifications

General IconGeneral
BrandCodan
Model2110 series
CategoryTransceiver
LanguageEnglish

Related product manuals