OTHER UPC/EAN OPTIONS ENTER/EXIT PROGRAMMING MODE
PRODUCT REFERENCE GUIDE
165
Price Weight Check
Enables/disables calculation and verification of price/weight check digits. Applies to all
UPC‐A and EAN/JAN‐13 labels with eligible
1
Number System/First Character digits.
Options are:
•Disable
•4‐digit
price/weight
•5‐digit
price/weight
•4‐digit
European price/weight
•5‐digit
European price/weight
To set this feature:
1. Scan the Enter/Exit Programming Mode barcode at the top of the page.
2. Scan the barcode representing the desired option below or on the following pages.
Y
ou’ll need to cover any unused barcodes on facing pages to ensure that the scanner
reads only the barcode you intend to scan.
3. Complete the programming sequence by scanning the Enter/Exit Programming Mode
bar
code.
Price Weight Check = Disable
Price Weight Check = 4-digit price/weight
Price Weight Check = 5-digit price/weight
1. Price Weight Check generally applies to UPC-A labels with a Number System Digit of 2 and EAN/
JAN-13 labels with a First Character of 2. There are a total of six flag digits corresponding to the six
types. Checking applies depending upon which type is enabled.
DEFAULT