READING PERFORMANCE
300
MAGELLAN™ 1500I
READING PERFORMANCE
Parameter Specification
Aiming LED aimer for precision scanning
Image Capture
1 MP; 1280 x 800 pixels;
Graphic Formats: BMP, JPEG
Print Contrast Ratio (Minimum) 25%
Read Height 14.0 cm / 5.5 in
Reading Angle Pitch: +/- 65°; Roll (Tilt): 0 - 360°; Skew (Yaw): +/- 75°
Reading Indicators
Beeper (Adjustable Tone and Volume); Datalogic
‘Green Spot’ Good
Read Feedback; Good Read LED
Resolution (Maximum) 0.130 mm / 5 Mils
READING RANGES
Parameter Specification
Typical Depth Of Field
Printing Resolution, Symbol Length, Sc
an Angle, Contrast and
Ambient Light Dependent
1D / Linear Codes
5 mils: 2.5 to 9.0 cm / 0.9 to 3.5 in
7.5 mils: 0 to 17.0 cm / 0 to 6.6 in
10 mils:
0 to to 21 cm / 0 to 8.2 in
13 mils: UPC: 0 to 25.0 cm / 0 to 9.8 in
20 mils: 1.0 to 30.0 cm / 0.4 to 11.8 in
2D Codes (Optional)
6.5 mils PDF: 2.5 to 11.0 cm / 0.9 to 4.3 in
13 mils Data Matrix: 0 to 17.0 cm / 0 to 6.7 in
16 mils PDF: 0 to 2.0 cm / 0 to 7.8 in
24 mils Data Matrix: 0 to 25.0 cm / 0 to 9.8 in
SAFETY & REGULATORY
Parameter Specification
Agency Approvals
The product meets necessary safety and r
egulatory approvals
for its intended use.
Environmental Compliance Complies to China RoHS; Complies to EU RoHS
LED Classification EN62471 and IEC62471 Lamp Illumination
Safety Standards UL/EN/IEC62368-1 and UL/EN/IEC60950-1