ENTER/EXIT PROGRAMMING MODE
48
MAGELLAN™ 1500I
Good Read Beep Length
Specifies the duration of a good read beep.
To set this feature:
1. Scan the Enter/Exit Programming Mode barcode at the top of the page.
2. Scan the barcode,
Set Good Read Beep Length on page 48. You’ll need to cover any
unused barcodes on this and the facing page to ensure that the scanner reads only
the
barcode you intend to scan.
3. Scan the appropriate digits from the
Alpha-Numeric Keypad in Appendix C that repre‐
sent the desired good read beep length setting. The selectable range is 1‐255, which is
the
timeout in 10‐millisecond increments. Times have a tolerance of +/‐25%. Pad all
single and double digit numbers with leading zeroes to yield a three‐digit entry (001‐
255).
Examples:
001 = 10ms
005 = 50ms
040 = 400ms
4. The scanner will automatically exit Programming Mode when the appropriate
amount of digits have been scanned
Set Good Read Beep Length
Default setting for this feature is:
008 - 80ms
.
DEFAULT