STANDARD 2 OF 5 ENTER/EXIT PROGRAMMING MODE
PRODUCT REFERENCE GUIDE
255
Standard 2 of 5 Length Control
This feature specifies whether variablelength or fixedlength decoding will be set for Stan
dard 2 of 5.
To set this feature:
1. Scan the Enter/Exit Programming Mode barcode at the top of the page.
2. Scan your selection from the barcodes below. You’ll need to cover any unused bar
codes on this and the facing page to ensure that the scanner reads only the barcode
y
ou intend to scan.
3. Complete the programming sequence by scanning the ENTER/EXIT Programming
Mode bar
code.
049700(CR)
Standard 2 of 5 Length Control = Variable Length
049701(CR)
Standard 2 of 5 Length Control = Fixed Length
DEFAULT

Table of Contents

Other manuals for Datalogic Magellan 1500i

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic Magellan 1500i and is the answer not in the manual?

Datalogic Magellan 1500i Specifications

General IconGeneral
TypeFixed bar code reader
Sensor typeLED
Scanner type2D
Yaw reading angle-75 - 75 °
Scanner resolution0.13 mm
Tilt reading angle0 - 360 °
Pitch reading angle-65 - 65 °
Light levels (direct sunlight)0 - 86.1 lx
Linear (1D) barcodes supported-
Optical sensor resolution (W x H)1280 x 800 pixels
2D (matrix & stacked) barcodes supportedAztec Code, Data Matrix, MaxiCode, QR Code
Input voltage5 V
Power consumption500 mA
Power source typeUSB
BuzzerYes
CertificationEN62471, IEC62471
Product colorBlack
Housing materialPlastic
Image formats supportedBMP, JPEG
International Protection (IP) codeIP52
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)0 - 40 °C
Operating relative humidity (H-H)5 - 95 %
USB version2.0
Connectivity technologyWired
Sustainability certificatesRoHS
Harmonized System (HS) code84716070
Weight and Dimensions IconWeight and Dimensions
Depth75 mm
Width60 mm
Height150 mm
Weight240 g