ENTER/EXIT PROGRAMMING MODE
PRODUCT REFERENCE GUIDE
25
SCANNING FEATURES
1D Double Read Timeout
The 1D Double Read Timeout feature specifies the minimum allowable time which must
pass before reading the same 1D label again (e.g. two identical items in succession).
To set the Double Read Timeout:
1. Scan the Enter/Exit Programming Mode barcode at the top of the page.
2. Scan your selection from the barcodes below. You’ll need to cover any unused bar
codes on this and the facing page to ensure that the scanner reads only the barcode
y
ou intend to scan.
3. Complete the programming sequence by scanning the Enter/Exit Programming Mode
bar
code.
NOTE
004D1E(CR)
1D Double Read Timeout = 300ms
004D28(CR)
1D Double Read Timeout = 400ms
004D3C(CR)
1D Double Read Timeout = 600ms
004D50(CR)
1D Double Read Timeout = 800ms
If the incidence of multiple reads is not acceptable, increase the Double Read
Timeout setting to a higher value.
DEFAULT