136
6-10-2-5. LOUDNESS STANDARD
Settings in this menu are common for the FA-95ALA in option slot A (channels 1 and 2)
and in option slot B (channels 1 and 2).
S T A N D A R D : A R I B
T A R G E T L V L : - 2 4 . 0 L K F S
M O M E N T A R Y : 4 0 0 m s e c
S H O R T T E R M : 3 0 0 0 m s e c
ARIB
ATSC A85
EBUR128
ITU R1770
Allows you to select the standard under which the
loudness measurement and adjustment will be
conducted.
ARIB: ARIB TR-B32
ATSC A85: ATSC A/85
EBU R128: EBU-R128
ITU R1770: ITU-R BS.1770
Displays the specified target level of the selected
standard.
Displays the specified measurement duration
(Momentary) of the selected standard.
Displays the specified measurement duration
(Short Term) of the selected standard.
Parameter Specification of Standards used in the FA-95ALA