199
*2 Selectable if Mode is set to 5.1ch.
*3 Under Loudness Channel Assign 2 menus, values are EMB2 CH1 6 respectively.
*4 Shown if the FA-95D-D or FA-95DE-E is installed in option slot A/B.
* LFE channels are subjected to adjustments, but not to measurement.
Loudness Standars Setting
Parameter
Default
Setting range
Description
Standard
ARIB TR-B32
ARIB TR-B32
ATSC A85
EBU-R128
ITU R BS.1770
Allows you to select according to what
standard the loudness measurement and
adjustment will be conducted.
Parameter Specification of Standards used in the FA-95ALA
Parameter
ARIB TR-B32
ATSC A/85
EBU-R128
ITU-R BS.1770
Target Level
-24.0 LKFS
-24.0 LKFS
-23.0 LUFS
-24.0 LKFS
Momentary Average Time
400 msec
125 msec
400 msec
400 msec
Short Term Average Time
3000 msec
10000 msec
3000 msec
3000 msec
Absolute Gating
-70.0 LKFS
NONE
-70.0 LUFS
-70.0 LKFS
Relative Gating
-10 LU
NONE
-10 LU
-10 LU
Overlap Size
75%
0%
75%
75%

Table of Contents