Remote control commandsMXO 4 Series
530User Manual 1335.5337.02 ─ 07
Usage: Query only
Asynchronous command
Manual operation: See "ProbeMeter" on page 130
PROBe<ch>:PMETer:RESults:POSitive?
Returns the R&S ProbeMeter measurement result of differential active R&S probes:
the voltage that is measured between the positive signal socket and the ground.
Suffix:
<ch>
.
1 to 4, index of the analog channel
Return values:
<Result> Range: -1E+26 to 1E+26
Increment: 0.001
*RST: 0
Default unit: V
Usage: Query only
Asynchronous command
Manual operation: See "ProbeMeter" on page 130
PROBe<ch>:SETup:ADVanced:AUDioverload <Sound>
Activates the acoustic overrange warning in the probe control box. The command is
relevant for R&S RT-ZHD probes.
Suffix:
<ch>
.
1 to 4, index of the analog channel
Parameters:
<Sound> ON | OFF
*RST: OFF
Usage: Asynchronous command
Manual operation: See "Audible overrange" on page 135
PROBe<ch>:SETup:ADVanced:FILTer <State>
Activates the lowpass filter in the probe control box. The filter frequency depends on
the probe type and is indicated on the probe control box.
Suffix:
<ch>
.
1 to 4, index of the analog channel
Parameters:
<State> ON | OFF
*RST: OFF
Usage: Asynchronous command
Acquisition and setup