Remote control commandsMXO 4 Series
704User Manual 1335.5337.02 ─ 07
SBUS<sb>:TYPE <Protocol Type>
Selects the bus type for analysis. The type of available buses depends on the installed
options.
Suffix:
<sb>
.
1...4, index of the serial bus
Parameters:
<Protocol Type> I2C | SPI | UART | CAN | LIN | SPMI | TNOS
Usage: Asynchronous command
Manual operation: See "Protocol type" on page 313
SBUS<sb>:RESult <ShwResTbl>
Enables a table with decoded data of the serial signal. The function requires the option
for the analyzed protocol.
Suffix:
<sb>
.
1...4, index of the serial bus
Parameters:
<ShwResTbl> ON | OFF
*RST: OFF
Usage: Asynchronous command
Manual operation: See "Show decode table" on page 316
SBUS<sb>:FORMat <DataFormat>
Sets the number format for decoded data values of the indicated serial bus. It defines
the format in the decode table, and in the combs of the decoded signal on the screen.
Suffix:
<sb>
.
1...4, index of the serial bus
Parameters:
<DataFormat> HEX | OCT | BIN | ASCII | ASCii | SIGN | USIG
*RST: HEX
Usage: Asynchronous command
Manual operation: See "Data format" on page 316
SBUS<m>:ZCOupling <ZoomCoupling>
If enabled, the protocol decode zoom and result table are synchronized.
Suffix:
<m>
.
1...4, index of the serial bus
Protocols