EasyManua.ls Logo

Rohde & Schwarz RTE Series - Page 1117

Rohde & Schwarz RTE Series
2078 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote control commands
R&S
®
RTE
1117User Manual 1326.1032.02 ─ 20
CHANnel<m>:BANDwidth............................................................................................. 1120
CHANnel<m>:CPLing...................................................................................................1120
CHANnel<m>:IMPedance............................................................................................. 1120
CHANnel<m>:OVERload.............................................................................................. 1121
CHANnel<m>:STATe <State>
Switches the channel signal on or off.
Suffix:
<m>
.
1..4
Selects the input channel.
Parameters:
<State> ON | OFF
*RST: OFF
Usage: Asynchronous command
CHANnel<m>:COUPling
<Value>
Selects the connection of the indicated channel signal.
Suffix:
<m>
.
1..4
Selects the input channel.
Parameters:
<Value> DC | DCLimit | AC
DC
Direct connection with 50 Ω termination, passes both DC and
AC components.
DCLimit
Direct connection with 1 MΩ termination, passes both DC and
AC components.
AC
Connection with 1 MΩ termination, removes DC and very low-
frequency components.
CHANnel<m>:GND <State>
Connects the signal to the ground.
Suffix:
<m>
.
1..4
Parameters:
<State> ON | OFF
*RST: OFF
Acquisition and setup

Table of Contents

Other manuals for Rohde & Schwarz RTE Series

Related product manuals