Instrument setup
R&S
®
RTE
144User Manual 1326.1032.02 ─ 20
Enable persistance......................................................................................................144
Infinite persistence...................................................................................................... 144
PersistenTime............................................................................................................. 144
Reset...........................................................................................................................145
Intensity.......................................................................................................................145
Style............................................................................................................................ 145
Color............................................................................................................................145
Set to default color...................................................................................................... 145
Use color table............................................................................................................ 145
Source.........................................................................................................................146
Assigned color table....................................................................................................146
Enable persistance
If enabled, each new data point in the diagram area remains on the screen for the
duration that is defined using PersistenTime, or as long as Infinite persistence is
selected.
If disabled, the waveform points are displayed only for the current acquisition.
Remote command:
DISPlay:PERSistence[:STATe] on page 1090
Infinite persistence
If infinite persistence is enabled, each new waveform point remains on the screen until
this option is disabled. Use infinite persistence to display rare events in the signal.
Remote command:
DISPlay:PERSistence:INFinite on page 1090
PersistenTime
Sets a time factor that controls how long the waveforms points fade away from the dis-
play. Thus, the R&S RTE emulates the persistence of analog phosphor screens.