Remote control commands
R&S
®
RTE
1636User Manual 1326.1032.02 ─ 20
TRIGger<m>:ARINc:DATA:MAX.................................................................................... 1637
TRIGger<m>:ARINc:ERRor:CODing..............................................................................1637
TRIGger<m>:ARINc:ERRor:PARity................................................................................1637
TRIGger<m>:ARINc:LABel:CONDition........................................................................... 1637
TRIGger<m>:ARINc:LABel:MIN.....................................................................................1637
TRIGger<m>:ARINc:LABel:MAX....................................................................................1638
TRIGger<m>:ARINc:MINGap:SELect.............................................................................1638
TRIGger<m>:ARINc:MINGap:BITS................................................................................1638
TRIGger<m>:ARINc:MAXGap:SELect............................................................................1638
TRIGger<m>:ARINc:MAXGap:BITS...............................................................................1638
TRIGger<m>:ARINc:SDI...............................................................................................1639
TRIGger<m>:ARINc:SSM............................................................................................. 1639
TRIGger<m>:ARINc:TYPE <Type>
Sets the trigger type for ARINC 429 analysis.
Parameters:
<Type> STARt | STOP | LABel | ERRor
*RST: STARt
TRIGger<m>:ARINc:DATA:CONDition <DataOperator>
Sets the condition for the data. You can define an exact data patterm or a data range.
Parameters:
<DataOperator> EQUal | NEQual | LTHan | LETHan | GTHan | GETHan |
INRange | OORange
EQUal | NEQual | LTHan | LETHan | GTHan | GETHan
Equal, Not equal, Less than, Less or equal than, Greater Than,
Greater or equal than. These conditions require one pattern to
be set with TRIGger<m>:ARINc:DATA:MIN.
INRange | OORange
In range/Out of range: set the minimum and maximum value of
the range with TRIGger<m>:ARINc:DATA:MIN and
TRIGger<m>:ARINc:DATA:MAX.
*RST: EQUal
TRIGger<m>:ARINc:DATA:MIN <DataMin>
Defines the minimum bit pattern for the data.
Parameters:
<DataMin> Numeric or string pattern, see Chapter 18.4.6, "Bit pattern
parameter", on page 1076. The string parameter accepts the bit
value X (don't care).