Remote control commands
R&S
®
RTE
1710User Manual 1326.1032.02 ─ 20
TRIGger<m>:SENT:SIMX <SMIDPatternTo>
Sets the end value of an identifier range for TRIGger<m>:SENT:SICN INRange or
OORange.
Parameters:
<SMIDPatternTo> Numeric or string pattern, Chapter 18.4.6, "Bit pattern parame-
ter", on page 1076. The string parameter accepts the bit value X
(don't care).
TRIGger<m>:SENT:SDCN <SMDataOperator>
Sets the operator to set a specific data pattern or a data pattern range.
Parameters:
<SMDataOperator> EQUal | NEQual | LTHan | LETHan | GTHan | GETHan |
INRange | OORange
EQUal | NEQual | LTHan | LETHan | GTHan | GETHan
Equal, Not equal, Less than, Less or equal than, Greater than,
Greater or equal than. These conditions require one data pattern
to be set with TRIGger<m>:SENT:SDMN.
INRange | OORange
In range / Out of range. To define the range set the minimum
and maximum values with TRIGger<m>:SENT:SDMN and
TRIGger<m>:SENT:SDMX.
*RST: EQUal
TRIGger<m>:SENT:SDMN <SMDataPattern>
Specifies a data pattern, or sets the start value of a data pattern range.
Parameters:
<SMDataPattern> Numeric or string pattern, Chapter 18.4.6, "Bit pattern parame-
ter", on page 1076. The string parameter accepts the bit value X
(don't care).
TRIGger<m>:SENT:SDMX <SMDataPatternTo>
Sets the end value of an identifier range for TRIGger<m>:SENT:SCONdition
INRange or OORange.
Parameters:
<SMDataPatternTo> Numeric or string pattern, Chapter 18.4.6, "Bit pattern parame-
ter", on page 1076. The string parameter accepts the bit value X
(don't care).
TRIGger<m>:SENT:FORMerror <FormError>
Triggers on format errors in serial messages.
Protocols