Protocol analysis
R&S
®
RTE
827User Manual 1326.1032.02 ─ 20
Only available for USB low speed and USB 2.0 full speed protocol types.
Reset ← Trigger type USB
Sets the trigger to the Reset field. For more information on the reset condition, see the
USB standard. The trigger instant is the end of the 10 ms period after the SE0 field.
Only available for USB low speed and USB 2.0 full speed protocol types.
Suspend ← Trigger type USB
Sets the trigger to the Suspend field. For more information on the suspend condition,
see the USB standard. The trigger instant will be declared after the defined 3 ms time-
out.
Only available for USB low speed and USB 2.0 full speed protocol types.
Resume ← Trigger type USB
Sets the trigger to the Resume field. For more information on the resume condition,
see the USB standard. The trigger instant will be declared after the defined 20 ms
timeout.
Only available for USB low speed and USB 2.0 full speed protocol types.
Token ← Trigger type USB
Sets the trigger to one out of four different token trigger types: OUT, IN, SOF, or
SETUP.
See "Token" on page 828
Data ← Trigger type USB
Sets the trigger to one out of four different data trigger types: DATA0, DATA1, DATA2,
or MDATA.
See "Data" on page 829
USB (option R&S