Protocol analysis
R&S
®
RTE
888User Manual 1326.1032.02 ─ 20
"Frame ID
max"
The second frame identifier pattern is required to specify a range with
conditions "In range" and "Out of range".
Remote command:
TRIGger<m>:CXPI:FID:CONDition on page 1883
TRIGger<m>:CXPI:FID:MAX on page 1883
TRIGger<m>:CXPI:FID:MIN on page 1883
DLC
Sets the data length code, which indicates the length of the data byte.
The DLC setup consists of the condition and one or two DLC patterns.
"Condition"
Defines the operator to set a specific DLC ("Equal" or "Not equal") or
a DLC range.
"DLC min /
DLC "
Defines the bit pattern of the DLC.
In binary format, use the following characters: 1; 0; or X (do not care).
To enter the pattern in other formats use the bit pattern editor, see
Chapter 13.1.5, "Bit pattern editor", on page 521.
"DLC max"
The second DLC pattern is required to specify a range with conditions
"In range" and "Out of range".
Remote command:
TRIGger<m>:CXPI:DLC:CONDition on page 1880
TRIGger<m>:CXPI:DLC:MAX on page 1880
TRIGger<m>:CXPI:DLC:MIN on page 1881
DLC Extend
Sets the extension data length code, which indicates the length of the data byte of a
long frame.
The DLC extend setup consists of the condition and one or two DLC patterns.
"Condition"
Defines the operator to set a specific DLC extend ("Equal" or "Not
equal") or a DLC extend range.
"DLC Extend
min / DLC
Extend"
Defines the bit pattern of the DLC extend.
In binary format, use the following characters: 1; 0; or X (do not care).
To enter the pattern in other formats use the bit pattern editor, see
Chapter 13.1.5, "Bit pattern editor", on page 521.
"DLC Extend
max"
The second DLC extend pattern is required to specify a range with
conditions "In range" and "Out of range".
Remote command:
TRIGger<m>:CXPI:DEXTension:CONDition on page 1879
TRIGger<m>:CXPI:DEXTension:MAX on page 1880
TRIGger<m>:CXPI:DEXTension:MIN on page 1880
Data
The data setup consists of the condition and one or two identifier pattern.
"Condition"
Defines the operator to set a specific data ("Equal" or "Not equal") or
a data range.
CXPI (option R&S RTE-K76)