Instrument Function
R&S
®
SMU200A
255Operating Manual 1007.9845.32 ─ 15
In the top section, the Level Sweep mode is activated and the sweep mode is selected.
The buttons are used to reset the level sweep (all sweep modes) or to execute the level
sweep ("Single" mode).
The level range for the sweeps is selected for instruments with Option High Power.
The sweep range, sweep spacing and dwell time are set in the bottom section.
State - Level Sweep
Activates Level Sweep mode.
Note: Activating the RF level sweep automatically deactivates the list mode, RF fre-
quency sweep and LF sweep.
In case of two-path instrument, this affects the respective path.
SCPI command:
[:SOURce<hw>]:POWer:MODE on page 768
Mode - Level Sweep
Selects the Level Sweep instrument operating mode and the Sweep mode.
"Auto"
Sets an automatic repeated sweep cycle. If a different sweep mode was
activated prior to the "Auto" mode, the cycle continues from the current
sweep setting.
The "Reset Sweep" button resets the sweep to the start frequency.
Example:
SOUR:SWE:POW:MODE AUTO
TRIG:PSW:SOUR AUTO
SOUR:POW:MODE SWE