Instrument Function
R&S
®
SMU200A
409Operating Manual 1007.9845.32 ─ 15
Assigned to Multi Seg. Waveform
Displays the name of the multi segment waveform file the current sequencing list file is
assigned to.
SCPI command:
n.a.
Sequencing Play List
The "Sequencing Play List" table is used to define the sequence in which the waveform
file segments are processed and how many times each of them is repeated.
Id# ← Sequencing Play List
Indication of the row number.
n.a.
State ← Sequencing Play List
Enables/disables the selected row. Only active segments are processed.
n.a.
Segment# ← Sequencing Play List
Indication of segment index.
The sequencing list file carries information only about the segment index, the corre-
sponding wavefile names are retrieved form the assigned multi segment waveform file.
n.a.
Waveform ← Sequencing Play List
Indication of the waveform file name of the segment. The file name is retrieved form the
assigned multi segment waveform file.
Available for selection are only waveform files from the pool of segments of the selected
multi segment waveform file.
n.a.
Repetition Cycles ← Sequencing Play List
Sets the number of times the selected segment is cyclically repeated before the next
segment in the sequence is processed.
n.a.
Next ← Sequencing Play List
Determines the action after completing the current one, like for instance which segment
is processed after the processing of the current one is finished.
"Next Id#"
The next active segment in the play list is processed.
"Blank"
After the processing of the current segment is completed, the signal out-
put is stopped until a signal restart like a retrigger signal is received.
A restart signal causes a complete restart of the sequencing play list.
"Endless"
The current segment is re-played until a signal restart like a retrigger
signal is received and the complete sequencing play list is restarted.
Only active segments are considered.