Remote Control Commands
R&S
®
SMU200A
587Operating Manual 1007.9845.32 ─ 15
Parameters:
float
0 to 2^20-1
1
0
Symbol
<Delay>
Range:
Increment:
*RST:
Default unit:
BB:ARB:TRIG:OUTP2:DEL 16
sets a delay of 16 samples for the signal on connector MARKER
2.
Example:
[:SOURce<hw>]:BB:ARB:TRIGger:OUTPut<ch>:DELay:MAXimum?
[:SOURce<hw>]:BB:ARB:TRIGger:OUTPut<ch>:DELay:MINimum?
The command queries the minimum marker delay for set-
ting :BB:ARB:TRIGger:OUTPut:DELay:FIXed ON.
Return values:
float<Minimum>
BB:ARB:TRIG:OUTP:DEL:FIX ON
restricts the marker signal delay setting range to the dynamic
range.
BB:ARB:TRIG:OUTP:DEL:MIN
queries the minimum of the dynamic range.
Response: 0
the minimum for the marker delay setting is 0 samples.
Example:
Query onlyUsage:
[:SOURce<hw>]:BB:ARB:TRIGger:RMODe?
The command queries the status of waveform output or all trigger modes with ARB on.
Return values:
STOP|RUN
RUN
The waveform is output. A trigger event occurred in the triggered
mode.
STOP
The waveform is not output. A trigger event did not occur in the
triggered modes, or waveform output was stopped by the
command:BB:ARB:TRIG:ARM:EXECute (armed trigger modes
only).
<Frequency>
SOURce Subsystem