EasyManua.ls Logo

Siemens SINAMICS G120 - Page 481

Siemens SINAMICS G120
750 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Connector/Binector (BICO)-Parameters
Parameters
1-481
© Siemens AG 2011 All Rights Reserved
SINAMICS G120 Control Units CU240B/E-2 Parameter Manual (LH11), 01/2011
r1077 CO: Supplementary setpoint effective / Suppl setpoint eff
r1078 CO: Total setpoint effective / Total setpoint eff
p1083[0...n] CO: Speed limit in positive direction of rotation / n_limit pos
r1084 CO: Speed limit positive effective / n_limit pos eff
p1086[0...n] CO: Speed limit in negative direction of rotation / n_limit neg
r1087 CO: Speed limit negative effective / n_limit neg eff
r1112 CO: Speed setpoint after minimum limiting / n_set n. min_lim
r1114 CO: Setpoint after the direction limiting / Setp after limit
r1119 CO: Ramp-function generator setpoint at the input / RFG setp at inp
r1149 CO: Ramp-function generator, acceleration / RFG acceleration
r1150 CO: Ramp-function generator speed setpoint at the output / RFG n_set at outp
r1169 CO: Speed controller, speed setpoints 1 and 2 / n_ctrl n_set 1/2
r1170 CO: Speed controller, setpoint sum / n_ctrl setp sum
r1258 CO: Vdc controller output / Vdc_ctrl output
r1298 CO: Vdc controller output (U/f) / Vdc_ctrl output
r1337 CO: Actual slip compensation / Slip comp act val
r1343 CO: I_max controller frequency output / I_max_ctrl f_outp
r1348 CO: U/f control Eco factor actual value / U/f Eco fac act v
p1351[0...n] CO: Motor holding brake starting frequency / Brake f_start
r1438 CO: Speed controller, speed setpoint / n_ctrl n_set
r1445 CO: Actual speed smoothed / n_act smooth
r1454 CO: Speed controller system deviation I component / n_ctrl sys dev Tn
r1468 CO: Speed controller P-gain effective / n_ctr Kp eff
r1482 CO: Speed controller I torque output / n_ctrl I-M_output
r1490 CO: Droop feedback speed reduction / Droop n_reduction
r1493 CO: Moment of inertia, total / M_inertia total
r1508 CO: Torque setpoint before supplementary torque / M_set bef. M_suppl
r1516 CO: Supplementary torque and acceleration torque / M_suppl + M_accel
r1518[0...1] CO: Accelerating torque / M_accel
p1520[0...n] CO: Torque limit upper / M_max upper
p1521[0...n] CO: Torque limit lower / M_max lower
p1524[0...n] CO: Torque limit upper/motoring scaling / M_max up/mot scal
p1525[0...n] CO: Torque limit lower scaling / M_max lower scal
r1526 CO: Torque limit upper without offset / M_max up w/o offs
r1527 CO: Torque limit lower without offset / M_max low w/o offs
r1538 CO: Upper effective torque limit / M_max upper eff
r1539 CO: Lower effective torque limit / M_max lower eff
r1547[0...1] CO: Torque limit for speed controller output / M_max outp n_ctrl
r1548[0...1] CO: Stall current limit torque-generating maximum / Isq_max stall
p1570[0...n] CO: Flux setpoint / Flux setpoint
r1593[0...1] CO: Field weakening controller / flux controller output / Field/Fl_ctrl outp
r1597 CO: Field weakening controller output / Field_ctrl outp
r1598 CO: Total flux setpoint / Flux setp total
r1718 CO: Isq controller output / Isq_ctrl outp
r1723 CO: Isd controller output / Isd_ctrl outp
r1732[0...1] CO: Direct-axis voltage setpoint / Direct U set
r1733[0...1] CO: Quadrature-axis voltage setpoint / Quad U set
r1770 CO: Motor model speed adaptation proportional component / MotMod n_adapt Kp
r1771 CO: Motor model speed adaptation I comp. / MotMod n_adapt Tn
r1801[0...1] CO: Pulse frequency / Pulse frequency
r1809 CO: Modulator mode actual / Modulator mode act
r2050[0...7] CO: PROFIBUS PZD receive word / PZD recv word
r2089[0...4] CO: Send binector-connector converter status word / Bin/con ZSW send

Table of Contents

Other manuals for Siemens SINAMICS G120

Related product manuals