12713020-003-2 Revision F.01 – January 2007 SSU-2000 Technical Reference 215
Chapter 3 ICS Command Reference
INPUT
Level 2 Same as Level 1 operation
Level 3 Same as Level 2 operation, with the following additions:
INPUT xAy[-z] {ESF|D4|CCS|CAS|1MHZ|1.544MHZ|2.048MHZ|5MHZ|6.312MHZ|
10MHZ}
INPUT xAy[-z] {ZS|SSM|CRC}{ON|OFF}
INPUT xAy[-z] PRIORITY {0-10}
INPUT xAy[-z] {ENABLE|DISABLE}
INPUT xAy[-z] SSM {4|5|6|7|8}
INPUT xAy[-z] PQL {1-16}
INPUT xAy[-1] GAIN {ON|OFF}
INPUT xAy[-z] CSFLT {HIGH|LOW|OFF}
INPUT xAy[-z] {LOS|AIS|OOF|BPV|CRC}{SET|CLR} value
INPUT xAy[-z] MTIE [{EL1|EL2|CL1|CL2}]{T10|T100|T1K| T10K|T100K}
value
INPUT xAy[-z] MTIE {PRS|DS1|G.811|G.823}
INPUT xAy[-z] FREQ {A|B}{SET|CLR|TAU} value
INPUT xAy[-a] 400HZ {ON|OFF}
Allows you to change the setting of a specified Input module.
Options are:
ESF|D4 Sets the T1 framing mode: ESF or D4. For use with the
DS1 Input module.
CCS|CAS (For E1) Sets the E1 framing mode: CCS or CAS. For use
with the E1 Input module.
1MHZ|1.544MHZ|2.048MHZ|5MHZ|10MHZ
Sets the Input module clock frequency when input is not
running in framing mode. Only the clock frequencies shown
are valid. If the input is a framed T1 signal, the CLK rate is
1.544MHz; if it is a framed E1 signal, the CLK rate is
2.048 MHz automatically. For use with the DS1 or E1 Input
module.
1.544MHZ|6.312MHZ
Sets the input frequency for the Japan Sine Input module.
SSM {ON|OFF} Enables or disables Sync Status Message reading. For
use with the DS1/E1 Input module.
ZS {ON|OFF} Enables or disables Zero Suppression. For use with the
DS1 or E1 Input module.
For DS1: On = B8ZS, Off = AMI
For E1: On = HDB3, Off = AMI
CRC {ON|OFF} Enables or disables CRC checking. For use with the DS1
or E1 Input module.
PRIORITY {0-10}
Sets Input priority level, where: 0 = monitor,
1 = highest priority, and 10 = lowest priority. For use with all
Input modules.