Chapter 3 ICS Command Reference
INPUT
216 SSU-2000 Technical Reference 12713020-003-2 Revision F.01 – January 2007
ENABLE Enables the specified input port on a DS1, E1, CC, or Sine
Input module.
DISABLE Disables the specified input port on a DS1, E1, CC, or Sine
Input module. This clears all alarms associated with an
input and disables setting of further alarms or use of the
input measurements.
SSM {4|5|6|7|8}
Sets the E1 SSM bit position. For use with the E1 Input
module.
PQL {1-16} Sets the Priority Quality Level (PQL) for the specified input
port on any Input module.
GAIN{ON|OFF} Enables or disables input gain setting. For use with the
DS1 or E1 Input module.
CSFLT {HIGH|LOW|OFF} Sets Cesium fault logic level. For use with the
DS1, E1, or Sine Input module.
HIGH
Alarm active when the fault is a high logic level.
LOW
Alarm active when the fault is a low logic level.
OFF
Default. Cesium fault is ignored (not the AIS).
MTIE [{EL1|EL2|CL1|CL2}]{T10|T100|T1K|T10K|T100K}
value
Sets MTIE Limit 1 or Limit 2 for 10/100/1000/ 10 000/
100 000 seconds threshold. If L1 or L2 are not provided,
both limits are implied. The Limit Range is [0 – 60 000]. For
use with the DS1, E1, GPS, or Sine Input module.
EL1 MTIE Error Limit 1
EL2 MTIE Error Limit 2
CL1 MTIE Clear Limit 1
CL2 MTIE Clear Limit 2
T10 MTIE 10-second period
T100 MTIE 100-second period
T1K MTIE 1000-second period
T10K MTIE 10 000-second period
T100K MTIE 100 000-second period
MTIE {PRS|DS1|G.811|G.823}
Sets MTIE Limit 1 or Limit 2 for predefined values
ANSI Specification –
PRS, DS1
ITU Specification – G.811, G.823
{AIS|BPV|CRC|LOS|OOF}{SET|CLR} value
Sets Error Count (SET) or sets Clear Count (CLR) of the
specified input hardware alarm signal. Range is 1 to 100.
For use with the DS1 or E1 Input module.
FREQ {A|B}{SET|CLR|TAU} value
Sets Frequency limits on Clock A or Clock B. For use with
the DS1, E1, GPS, or Sine Input module.
SET Sets Frequency Error Count
CLR Sets Frequency Clear Count

Table of Contents

Other manuals for Symmetricom SSU-2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom SSU-2000 and is the answer not in the manual?

Symmetricom SSU-2000 Specifications

General IconGeneral
BrandSymmetricom
ModelSSU-2000
CategoryPower Supply
LanguageEnglish

Related product manuals