Operating the transceiver from a computer
Manpack Transceiver 2110 series Reference Manual 459
ERROR: Selfid too long The self address or the total length of the self address and network
name exceeds a specified limit for the call system used in the
network. Shorten the length of the self address and/or the network
name.
ERROR: Sideband not
allowed
The sideband is not permitted for this channel. Select another mode.
ERROR: Synthesiser is
unlocked
You cannot transmit while the synthesiser is unlocked. Switch the
transceiver off then on again. If the error persists, contact your Codan
representative.
ERROR: System is busy There has been a problem making the call or updating the self address
list. Wait for a few minutes, then repeat the command.
ERROR: System locked The system is locked and the command cannot be executed. Wait for
the lock to be released (for example, a data call ending), or to timeout,
then try the command again.
ERROR: Too many group
IDs
You are making a call using the Group Selective address syntax,
however you have entered too many addresses (see page 406,
Addresses in commands).
ERROR: Transceiver cut
out
The PTT has timed out according to the value set in the Cfg PTT
Cutout Time entry in the Control List. If your transmission is long, set
the Cfg PTT Cutout Time entry to 30 minutes.
ERROR: Transceiver is
tuning
The PTT command has been rejected because the transceiver is
currently tuning. Wait until the transceiver completes the tuning
cycle, then try the ptt command again.
ERROR: Transmit
inhibited
You have tried to transmit on a receive-only channel. Select a channel
that has a transmit frequency.
ERROR: Tx disabled
because of TPE link
You are not permitted to transmit a signal due to the current position
of the TPE link and the programming options installed in your
transceiver. Contact your Codan representative.
ERROR: Unable to send
data
There has been a problem sending data with the call. This message is
preceded by a message stating the reason for the data not being sent.
Refer to the description for the previous message to resolve the
problem.
ERROR: Unknown network
name in selfid
The network for the self address does not exist as the network may
have been deleted after it was allocated to the self address. Program
the network into the Network List in your transceiver, or edit the self
address so that it uses a current network.
ERROR: XR or VP not
installed
You have attempted to use a voice encryptor option that is not
installed in your transceiver. If you want to use this option, contact
your Codan representative.
Table 70: CICS error messages (cont.)
Error message Description