SCAN OPERATION
12-12
D Select Memory scan
The Select Memory scan searches for signals through
Memory channels specified as ” (Select).
NOTE: For a Select Memory scan to start, two or
more Memory channels must be designated as Se-
lect Memory channels. (See below)
Follow steps q q through e as described on page 12-
10 to display the “SCAN” screen.
Touch [MEMO]( w D) for 1 second, and then touch
“SEL-MEMO” to start the Select Memory scan.
The MHz and kHz decimal points, and “SEL–MEMO
SCAN” blink while scanning.
If
“Up/Down” is selected as
the “MAIN DIAL (SCAN)” op-
tion
in the Scan Set mode, rotating the Dial changes the
scanning direction. (p. 12-4)
Push [MEMO]( e D) to cancel the scan.
While Select Memory scanning
Touch [MEMO]
for 1 second.
Touch
“SEL-MEMO.
Appears
Memory scan (Memory mode) (Continued)
L
eft
R
ight
C
enter
D
isplay
The L, R, C or D in the
instructions indicate the
part of the controller.
L: Left side
R: Right side
C: Center bottom
D: Display (Touch screen)
Previous view

Table of Contents

Other manuals for Icom IC-7100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Icom IC-7100 and is the answer not in the manual?

Icom IC-7100 Specifications

General IconGeneral
Supply13.8 V DC ±15%
Voltage13.8 V DC
Operating Temperature-10°C to +60°C
Frequency Coverage0.030-199.999 MHz, 400-470 MHz
ModesSSB, CW, AM, FM, DV
Output PowerHF/50MHz: 100W, 144MHz: 50W, 430MHz: 35W
Receiver TypeSuperheterodyne
Antenna ConnectorSO-239 (HF/50MHz/144MHz), N-type (430MHz)
WeightMain unit: 2.3 kg
TypeBase/Mobile
Frequency Range TX1.8–54 MHz, 144–148 MHz, 430–450 MHz
Frequency Range RX0.030–199.999 MHz, 400–470 MHz
Memories505
Current ConsumptionTX: 22 A, RX: 1.2 A