4. Remove the battery and/or install the new battery in the battery compartment.
5. Check the cover gasket to make sure it is clean and in good condition.
6. Install the battery compartment cover at the back of the instrument, and then
tighten the two thumb screws to complete the installation.
Figure 111 Removing the lithiumion battery
1.4.4 Alkaline Batteries
The NORTEC 600 includes a battery holder (Olympus P/N: 600-BAT-AA [U8780295]).
This holder accommodates eight AA-size alkaline batteries for situations where an
AC power source is not available and the internal Li-ion battery is discharged. When
operated under typical inspection conditions, the alkaline batteries typically provide
three hours of continuous operation.
To install the alkaline battery holder
1. Unfold the instrument stand (see Figure 1-12 on page 33).
2. Loosen the two thumb screws securing the battery compartment cover at the back
of the instrument, and then remove the battery compartment cover.
3. Remove the lithium-ion battery, if installed.
4. Install eight AA-size alkaline batteries into the alkaline battery holder.
5. Connect the alkaline battery holder connector to the instrument.
Battery
compartment
cover
Thumb screws
(two)
Battery
Stand