RL78/F13, F14 CHAPTER 15 SERIAL ARRAY UNIT
R01UH0368EJ0210 Rev.2.10 977
Dec 10, 2015
15.7.3 Calculating baud rate
(1) Baud rate calculation expression
The baud rate for UART (UART0, UART1) communication can be calculated by the following expressions.
(Baud rate) = {Operation clock (fMCK) frequency of target channel} ÷ (SDRmn[15:9] + 1) ÷ 2 [bps]
Caution Setting serial data register mn (SDRmn) SDRmn[15:9] = (0000000B, 0000001B) is prohibited.
Remarks 1. When UART is used, the value of SDRmn[15:9] is the value of bits 15 to 9 of the SDRmn register
(0000010B to 1111111B) and therefore is 2 to 127.
2. m: Unit number (m = 0, 1), n: Channel number (n = 0, 1), mn = 00, 01, 10, 11
The operation clock (f
MCK) is determined by serial clock select register m (SPSm) and bit 15 (CKSmn) of serial mode
register mn (SMRmn).

Table of Contents

Other manuals for Renesas RL78 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Renesas RL78 Series and is the answer not in the manual?

Renesas RL78 Series Specifications

General IconGeneral
CoreRL78
CPU Clock SpeedUp to 32 MHz
Flash MemoryUp to 512 KB
RAMUp to 32 KB
Operating Voltage1.6 V to 5.5 V
Low Power ModesHALT, STOP, SNOOZE
CPU Architecture16-bit
Temperature Range-40°C to +85°C
PackageLQFP
Timers16-bit timers
Communication InterfacesUART, I2C, LIN
A/D Converter12-bit

Related product manuals