EasyManua.ls Logo

Renesas RL78 Series

Renesas RL78 Series
1879 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RL78/F13, F14 CHAPTER 20 EVENT LINK CONTROLLER (ELC) (RL78/F14 Only)
R01UH0368EJ0210 Rev.2.10 1471
Dec 10, 2015
20.2.2 Timer input select register 0
The timer array unit channels 0 to 3 change the event input from the ELC to the source for each channel. For details, see
6.3.8 Timer input select register 0 (TIS0).
20.2.3 A/D converter mode register 1 (ADM1)
This register has the function of specifying the A/D conversion trigger. A/D conversion is performed by two-bit control and
using the signal by the TAU0 channel 1, event signal by the ELC, or pretimed signal/alarm interrupt signal as triggers. For
details, see 12.3.3 A/D converter mode register 1 (ADM1).
20.2.4 D/A converter mode register (DAM)
This register has the real-time output function, which starts D/A conversion using the event input from the ELC as triggers.
For details, see 13.3.3 D/A converter mode register (DAM).

Table of Contents

Other manuals for Renesas RL78 Series

Related product manuals