RL78/F13, F14 CHAPTER 14 COMPARATOR (RL78/F14 Only)
R01UH0368EJ0210 Rev.2.10 778
Dec 10, 2015
14.2 Registers to Control the Comparator
The comparator is controlled by using the following registers.
Table 14-3. Registers to Control the Comparator
Register Name Symbol After Reset Address Access Size
Peripheral Enable Register 1 PER1 00H F02C0H 8
Comparator Control Register CMPCTL 00H F02A0H 1, 8
Comparator I/O Select Register CMPSEL 00H F02A1H 1, 8
Comparator Output Monitor Register CMPMON 00H F02A3H 1, 8
A/D port configuration register ADPC 00H F0076H 8
D/A converter mode register 2 DAM2 00H F0227H 1, 8
Port mode register 4 PM4 FFH FFF24H 1, 8
Port mode register PM8 FFH FFF28H 1, 8
14.2.1 Peripheral Enable Register 1 (PER1)
The PER1 register enables or disables clock supply to each peripheral hardware unit. Clock supply to a hardware unit
that is not used is stopped in order to reduce the power consumption and noise.
When the comparator is used, be sure to set bit 5 (CMPEN) of this register to 1.
The PER1 register can be set by a 1-bit or 8-bit memory manipulation instruction.
Reset signal generation clears this register to 00H.
Figure 14-2. Format of Peripheral Enable Register 1 (PER1)
Address: F007AH After reset: 00H
Symbol <7> <6> <5> <4> <3> 2 1 <0>
PER1
DACEN
Note
TRGEN
CMPEN
Note
TRD0EN DTCEN 0 0 TRJ0EN
Note Only for the RL78/F14.
Cautions 1. When setting the comparator, be sure to set the CMPEN bit to 1 first. If CMPEN = 0,
writing to a control register of the comparator is ignored, and all read values are default
values (except for port mode registers 4 and 8 (PM4 and PM8), and port registers 4 and
8 (P4 and P8)).
2. Be sure to clear the following bits to 0.
RL78/F13: bits 1, 2, 5, 6, and 7
RL78/F14: bits 1, 2, and 6
CMPEN
Note
Control of comparator input clock R/W
0 Stops input clock supply.
• SFR used by the comparator cannot be written to.
• The comparator is in the reset state.
R/W
1
Supplies input clock.
• SFR used by the comparator can be read/written to.

Table of Contents

Other manuals for Renesas RL78 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Renesas RL78 Series and is the answer not in the manual?

Renesas RL78 Series Specifications

General IconGeneral
CoreRL78
CPU Clock SpeedUp to 32 MHz
Flash MemoryUp to 512 KB
RAMUp to 32 KB
Operating Voltage1.6 V to 5.5 V
Low Power ModesHALT, STOP, SNOOZE
CPU Architecture16-bit
Temperature Range-40°C to +85°C
PackageLQFP
Timers16-bit timers
Communication InterfacesUART, I2C, LIN
A/D Converter12-bit