RL78/F13, F14 CHAPTER 18 CAN INTERFACE (RS-CAN LITE)
R01UH0368EJ0210 Rev.2.10 1308
Dec 10, 2015
18.3.17 CAN Receive Rule Number Configuration Register (GAFLCFG)
Address GAFLCFGL: F0330H, GAFLCFGH: F0331H
b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0
— — — — — — — — — — — RNC0[4:0]
After Reset 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
Bit Symbol Bit Name Description R/W
15 to 5 Reserved These bits are always read as 0. R
4 to 0 RNC0[4:0] CANi Receive Rule Number Set Set the number of receive rules of channel 0.
Set these bits to a value within a range of H'00 to H'10.
R/W
Modify the GAFLCFG register only in global reset mode.
Up to 16 rules can be registered in the receive rule table.
RNC0[4:0] Bits
These bits are used to set the number of rules to be registered in the channel 0 receive rule table.
Set these bits to a value within a range of H'00 to H'10.