SC No. Type Error Name/Error Condition/Major Cause/Solution
The external controller error is detected due to other reason shown in
SC910-01 to -03.
Refer to the instructions for the external controller
Turn the main power OFF/ON.
SC No. Type Error Name/Error Condition/Major Cause/Solution
SC919-00 D External controller down
While EAC (External Application Converter), the conversion
module, was operating normally, the receipt of a power line
interrupt signal from the FLUTE serial driver was detected, of
BREAK signal from the other station was detected.
External controller and the machine had been operating correctly (*) but
the external controller was turned off or rebooted, or the video bus was
disconnected.
* Printing or scanning using the external controller.
Turn the main power OFF/ON.
SC No. Type Error Name/Error Condition/Major Cause/Solution
SC925-00 B NetFile function error
SC925-01 B NetFile function error
The NetFile file management on the HDD cannot be used, or a NetFile
management file is corrupted and operation cannot continue.
HDD defective
HDD inconsistency caused by power failure during HDD access,
etc.
Software bug
Service Call 900-998