Anti-Condensation Heater for Paper Feed
Trays
• Unplug the machine power cord before starting the following procedure.
• Do the following procedure not to damage any harnesses.
• Check that harnesses are not damaged or pinched after installation.
Accessory Check
Anti-Condensation Heater (Service Option) for Main Unit
No. Description Q’ty Remarks
1 Tray heater 1
2 Tapping screw: M3 X 8 1
3 PCB: DHB 1
4 Harness for tray 1
5 Harness for DC 1
6 Harness for AC 1
7 Tapping screw: M3 X 6 3
Anti-Condensation Heater (Service Option) for Optional PFU and LCIT
No. Description Q’ty Remarks
1 Tray heater 1
2 Harness 1
3 Spring screw:M4 X 10 1
2. Installation
128
RTB 55
Additional information