The shield detection feeler never moves while moving the shield drive gear by hands or fingers:
Locked.
Solution
By tilting the fusing unit, you can check whether the feeler does not move smoothly due to burrs on a part
in the unit, and remove the burrs.
1. Tilt the fusing unit [A] approx. 30°.
2. Put the fusing unit back to the horizontal position.
3. Perform the checking procedures (Fusing Shield Check).
There is no blockage: Resolved
There is a blockage: Not resolved
4. Tilt the fusing unit [A] approx. 30° in the opposite direction from step 1.
There is no blockage: Resolved
There is a blockage: Not resolved
6. Troubleshooting
1064