Process Control Operative Condition Related SPs
1
PowerON
ProCon :Set
When a certain time has passed after the
previous job end
(Except when recovering from an SC or
jam)
SP3-530-001
SP3-530-002
SP3-530-003
SP3-530-004
SP3-530-005
SP3-530-006
SP3-530-007
SP3-530-008
2 JobEnd ProCon :Set
When the value of the job end counter
becomes more than the threshold
(At job end)
SP3-534-001 to 004
SP3-534-011 to 014
3 Interrupt ProCon :Set
When the value of the job interrupt
counter becomes more than the threshold
SP3-533-001 to 004
SP3-533-011 to 014
4
Non-useTime
Procon :Set
When the value of the non-use time
counter becomes more than the threshold
SP3-531-001 to 004
5 Manual ProCon :Exe When SP 3-011 is used SP3-011-001 to 005
6 Toner End Recovery
After the Toner End Status is cleared
(Recovery is NOT done in the near end
status)
-
7
Initial Developer
Setting Process
Control
When the machine detects a new PCU or
development unit
-
Result Code for Executing Process Control
Check the following SPs.
• SP3-012-001-010 (Front)
• SP3-012-011-020 (Center)
• SP3-012-021-030 (Rear)
Category Code Result name Description
7. Detailed Descriptions
1220