EasyManua.ls Logo

Ricoh MP C3004 - SC500 (Engine: Fusing); Heating Sleeve (Center) Error (SC54*-**)

Ricoh MP C3004
2154 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SC No. Type Error Name/Error Condition/Major Cause/Solution
During motor ON, after checking the motor error notification registers
(err_velo and err_posi) for 500msec, the error state of either register was
detected at least 5 times.
Motor defective
Connector disconnected
Harness broken
IOB defective
Encoder defective
Replace the motor.
Reset the connector.
Replace the harness.
Replace the Paper Transport IOB.
SC500 (Engine: Fusing)
Heating Sleeve (Center) Error (SC54*-**)
SC No. Type Error Name/Error Condition/Major Cause/Solution
SC530-00 D Fusing Exhaust Fan Lock
In the motor ON state, the value of the lock sensor is checked every
100msec.
If a lock signal is not obtained for 50 times consecutively.
Motor defective
Connector disconnected
Harness broken
IOB defective
Replace the fusing exhaust fan.
Reconnect the connector.
Replace the harness.
Replace the Paper Transport IOB.
6. Troubleshooting
914

Table of Contents

Related product manuals