SP5-810-002 [SC Reset: Hard High Temp. Detection]
Clears the fusing hardware SC.
SP3-701-116 [Manual New Unit Set: #Fusing Belt].
Sets the new unit detection flag ON/OFF.
Pressure Roller
Adjustment before replacing the pressure roller
Before replacing the Pressure Roller, set SP3-701-118 to "1" and switch the power OFF. Then replace
the Pressure Roller and switch the power ON.
SP3-701 (Manual New Unit Set)
This SP is the new unit detection flag.
0: new unit detection flag OFF, 1: new unit detection flag ON
Item SP
Pressure Roller SP3-701-118
Replacement
Do not remove or adjust the pressure adjusting screws [A] when replacing the pressure roller.
The fusing unit is adjusted in the factory to match the hardness of the pressure roller, so that the nip
width will be correct.
Fusing Unit