[C]: 7 scale marks in 2mm intervals
[D]: Center mark
2. Change the position of the standard bracket by rotating it 180 degrees as shown below.
This makes the docking bracket easier to slide horizontally. Then reattach the docking
bracket to the mainframe.
[A]: Reverse
If the paper shifts towards the front
Slide the docking bracket towards the front side by the amount of shift, to move the finisher in the
same direction.
e.g.: When the paper has shifted by 2 mm towards the front from the center mark (2 mm/division
of the scale), move the docking bracket towards the front by 2 mm (2 divisions). The divisions move
towards the rear.
[A]: Proof Tray
[B]: Docking Bracket Screw